Rosemount 3051SFA Annubar flowmeter is equipped with patented averaging pitot tube, which can provide excellent measurement accuracy in a wide flow range, and it is a quality solution. The patented T-shaped sensor is equipped with an integrated thermal sleeve, which can obtain the measured value through a single pipe hole, while maintaining a small size in the pipeline, which can reduce the permanent pressure loss and save energy consumption. The flowmeter also has built-in flow calculation, which is used to fully compensate the mass flow measurement, and provides a variety of communication protocols, including WirelessHART®.
Specifications
The range ratio is as high as 200:1(14:1 flow range ratio).
Measuring range: differential pressure is as high as 2.48bar (1000inH2O), absolute pressure is as high as 250.00bar (3626psia), and gauge pressure is as high as 250.00bar (3626psig).
Pipe diameter 2 to 96in.(50 to 2440mm)
Outputs: differential pressure, static pressure, process temperature, scale variables, mass flow, volume flow and energy flow.
protocol
4-20 mA HART®、WirelessHART®、FOUNDATION™ Fieldbus
Process liquid contact material: 316 stainless steel, alloy C-276
diagnose
Basic diagnosis, loop integrity, process intelligence, plug-in pressure pipe
Update rate: 1 second to 60 minutes, user selectable.
Wireless range
Long distance (225 m), extended range (800 m), split (225 m) and high gain split (1 km).