Rosemount 3051SAL wireless level transmitter applies WirelessHART® technology, which is an excellent solution to optimize liquid level measurement. You can choose direct installation, split installation, balanced system and Tuned-System™ components. This wireless device can meet various process requirements. The transmitter adopts airtight stainless steel SuperModule™ platform, which has 15-year limited warranty and stability, and its power module has a service life of up to 10 years, which can ensure the reliability on site.
Specifications
The maximum working pressure is up to 10,000psi (689.48 bar).
The process temperature range is based on the filling liquid: the highest is 770°F (410°C), and the lowest is-157 F (-105 C).
Communication protocol WirelessHART®
Types of sealing system: direct installation, remote installation, adjusting system and balancing system.
The transmitter connector can be repaired and welded, and the connector is fully welded.
Flange type: ANSI/ASME, EN/DIN, GOST and JIS.
Thread type: NPT, DIN, ISO
Sanitary type
Process liquid contact material
316L stainless steel, alloy C-276, alloy 400, tantalum, gold-plated alloy 400, and gold-plated 316L stainless steel. See the complete specifications for a complete material list.
diagnose
Basic diagnosis, loop integrity, process intelligence, plug-in pressure pipe
Update rate
1 second to 60 minutes, user selectable.
Wireless range
Long distance (225 m), extended range (800 m), split (225 m) and high gain split (1 km).